Specifications
| MEASUREMENT PERFORMANCE | |
| Measurement Range | 0-1 aw, 0 -100% RH |
| Moisture Accuracy (including non-linearity, hysteresis, and repeatability) | 0 – 0.9 aw ± 0.02 aw, 0.9 – 1.0 aw ± 0.03 aw |
| Response time in oil flow (typical) | < 1 min (dry-wet) |
| Temperature Accuracy at +68°F (+20°C) | ± 0.36°F (0.2°C) |
| OPERATING ENVIRONMENT | |
| Electromagnetic compatibility | EN61326-1 |
| Ambient temperature | -40…60 °C (-40…140 °F) |
| Storage temperature | -40…80 °C (-40…176 °F) |
| Oil temperature | -40…100 °C (-40…212 °F) |
| Oil flow | Some flow recommended |
| Pressure Rating | 0…200 bar (0…2900 psi) |
| Fluid compatibility¹ | Petroleum based and synthetic fluids |
| INPUTS & OUTPUTS | |
| Analog current output | 0 – 20 mA, 4 – 20 mA |
| Analog voltage output | 0 – 5 V, 0 – 10 V |
| Digital output | RS-485, MODBUS RTU |
| MECHANICAL SPECIFICATIONS | |
| Electrical connection | M12 8-pin plug |
| Connection | G1/2’’ BSP |
| Supply voltage | 21-28 VDC |
| Supply current | 20 mA + load current |
| Housing / protection rating | Stainless steel (AISI 316L) / IP66 |
¹The MCS is not suitable for water-based fluids or aerospace phosphate ester hydraulic fluids.